MedicaseHub MC-063
Case MC-063 Emergency Source Int J Surg Case Rep, 2026 Reviewed 18 Nov 2026

She slipped between two boats and fell onto the flagpole

A 61-year-old woman fell onto a boat's flagpole. It went through both of her lungs and the middle of her chest, passing between her windpipe and gullet just above the aorta. She stayed awake and stable the whole time, and it was too long to fit in the scanner.

Researched and reviewed by Dr. Eron Shehu Sources selected and verified by a doctor. Drafts are prepared with AI assistance and checked line by line against those sources before publication. How we work.
Specialty
Thoracic surgery, trauma
Patient
Woman, 61
Accident
Slipped stepping from one boat to another and fell onto a flagpole
Path
In through the left chest, across the middle of the chest above the aortic arch, into the right lung
On arrival
Fully alert, normal blood pressure and pulse, 2 hours after the fall
Operation
Chest opened across both sides (clamshell); pole drawn out; 130 mL blood lost
Day 18
To rehabilitation; right hand weak from nerve injury
~3 years
Can make a fist; some hand muscles still paralysed
the fallbetween boats
  1. the fallbetween boats
  2. 2 hourstoo long to scan
  3. theatreclamshell
  4. 3 yearsthe hand
the fall · between boats

One wrong step

The woman was 61. She slipped while moving from one boat to another and fell onto the boat's flagpole, which went into her chest.

The local fire brigade cut through the pole with a cold saw, a metal-cutting saw that produces little heat or sparks, so she could be freed and moved with the rest of the pole still in her. She was given tranexamic acid, a drug that slows the breakdown of blood clots, and oxygen, and was flown about 43 miles to the major trauma centre at University Hospital Zurich in Switzerland. She arrived in the trauma room two hours after the accident.

FIG 1the slip, the path, the way outoriginal diagram
Three panels. The first shows a woman slipping between two boats and falling onto a flagpole. The second is a simplified front view of the chest with numbered points: the pole entered high on her left side near the back, passed between the windpipe and the gullet, crossed just above the aortic arch, and ended in the tip of the right lung. The third is the sequence of care, from cutting the pole at the scene and cutting it shorter again for the CT scan, to the operation, rehabilitation from day 18 and her hand at nearly three years.
Simplified. About 30 centimetres of pole crossed both lungs and the middle of the chest without hitting a major vessel.
2 hours · too long to scan

Awake, stable, and impaled

She arrived fully alert, with a normal blood pressure and heart rate. She needed some extra oxygen through a face mask but had no other injuries. The doctors heard a wheeze over the top of her left lung; her heart sounds were normal.

PhotographThe cut end of the flagpole in her left side on arrival, with the flag still attached. Graphic. Tap to show.
FIG 2on arrivalphotograph · CC BY 4.0
A patient lying on her side under blue covers, with the cut metal end of a flagpole sticking out of her left side and a red flag still wrapped around it, marked by a yellow arrow.
On arrival: the cut end of the pole, with the red flag still on it (arrow). From Schumacher J et al. Int J Surg Case Rep 2026, cropped by MedicaseHub. CC BY 4.0.

A chest X-ray showed a metal object about 30 centimetres long crossing her chest from the left side towards the right. It had gone in very far back on the left and was angled upwards, towards the neck, which meant it had almost certainly passed through the middle of the chest, the mediastinum, where the heart, the great blood vessels, the windpipe and the gullet all sit close together.

Because she was stable, the team wanted a CT scan with contrast to map exactly what the pole had hit. The pole was too long to go through the scanner, so the fire brigade came into the hospital and cut it shorter again with the cold saw. Throughout, from the scene to the operating table, someone held the pole still so it could not move inside her. The authors write that one person was given that single job for several hours.

The CT showed the path. The pole had entered the left side of the chest between the third and fourth ribs, gone through the upper lobe of the left lung, crossed the mediastinum close to the left subclavian artery, the artery to the left arm, narrowly missing the arch of the aorta, and passed between the windpipe and the gullet before ending in the tip of the right lung. There was a small collapse of both lungs from air leaking into the chest.

FIG 3the X-ray and CTX-ray · CT · CC BY 4.0
On the left, a chest X-ray with a long bright straight object crossing the upper chest diagonally; on the right, a coronal CT slice showing the pole running across the top of the chest, above the heart and between the lungs.
The chest X-ray (left) and a CT slice along the pole (right): it crosses the top of the chest above the heart. From Schumacher J et al. Int J Surg Case Rep 2026, cropped by MedicaseHub. CC BY 4.0.
FIG 4in three dimensionsCT reconstruction · CC BY 4.0
A three-dimensional CT reconstruction showing the lungs in blue, the heart and great vessels in red, and the pole passing over the top of the heart.
A 3D reconstruction: the lungs in blue, the heart and great vessels in red, and the pole crossing just above them. From Schumacher J et al. Int J Surg Case Rep 2026, cropped by MedicaseHub. CC BY 4.0.

The CT could not completely rule out a tear in the windpipe or the gullet, so before surgery the team looked inside both with cameras: a bronchoscopy for the airway and an oesophagoscopy for the gullet. The pole was pressing on the front wall of the gullet and pushing the windpipe slightly aside, but neither was torn.

theatre · clamshell

Opening the chest from side to side

The team prepared for the worst. Catheters were placed in the artery and vein in her groin so that she could be put on a heart-lung machine quickly if a major vessel started to bleed, and a breathing tube with two channels was used so that either lung could be ventilated on its own.

Two senior thoracic surgeons operated. They used a clamshell incision: a cut across the front of the chest along the fourth rib space on both sides, through the breastbone, so that the whole front of the chest opens upwards like a lid. It gives access to both lungs and to everything in the middle of the chest at once, which is what a pole crossing from one side to the other required, and it is the incision the hospital routinely uses for lung transplants.

Inside, the pole had gone through the upper lobes of both lungs and across the mediastinum just above the aortic arch. It was drawn out slowly under direct vision. The aorta had only a minor injury to its outer layer, which was not bleeding and was left alone. The tears in both lungs were stitched, and a small artery in the left upper lobe was tied off. The windpipe was not injured. Four chest drains were placed. The operation took two and a half hours, and she lost 130 millilitres of blood, about half a cup.

PhotographsViews inside the open chest during the operation. Graphic. Tap to show.
FIG 5the operationphotograph · CC BY 4.0
Two close-up photographs inside an open chest, showing red lung and fatty tissue with yellow arrows pointing to the track of the pole and the area of the aortic arch.
Inside the chest: the track of the pole through the mediastinum (left) and the minor injury to the outer wall of the aortic arch (right), marked by arrows. From Schumacher J et al. Int J Surg Case Rep 2026, cropped by MedicaseHub. CC BY 4.0.
FIG 6what came outphotograph · CC BY 4.0
The pieces of a metal flagpole with a red flag attached laid out on a blue drape next to a ruler, with an arrow marking a length of about 30 centimetres.
The pieces of the flagpole after removal, with the red flag, and the approximately 30 cm length marked. From Schumacher J et al. Int J Surg Case Rep 2026, cropped by MedicaseHub. CC BY 4.0.
3 years · the hand

The one lasting injury

Her breathing tube came out seven hours after surgery, and she spent three days in intensive care. Camera checks of the gullet and airway on the first and second days confirmed they were intact. The last chest drain came out on day 8, after an air leak from the injured lungs had settled.

After the operation she had tingling, nerve pain and weakness in her right hand, especially in bending the wrist and moving the fingers. An MRI showed swelling and bruising around part of the brachial plexus, the bundle of nerves from the neck to the arm, on the right, with no nerve cut through. The authors think the pole, which ended near the top of the right side of the chest, irritated those nerves. They note two other possible contributors: she had had an operation on a nerve root in her neck on the same side three years earlier, which no one knew about when she arrived, and arm positioning during chest surgery can stretch these nerves.

She left hospital on day 18 for a neurological rehabilitation centre. At three months she could lift her right arm and turn her hand, with largely normal feeling. Nearly three years after the accident, nerve tests showed the muscles supplied by two of the hand's three main nerves recovering steadily, while those supplied by the third, the ulnar nerve, were still paralysed. She could make a fist again, her nerve pain was controlled with medication, and physiotherapy and occupational therapy were continuing.

The longer view

Why the middle of the chest is so dangerous

Injuries that cross the mediastinum are among the most lethal in trauma. The authors cite death rates of up to 60%, and in gunshot wounds through the mediastinum about half of patients have an injured major vessel. The heart, the aorta and its branches, the windpipe and the gullet are packed so tightly that anything crossing the space rarely misses all of them. To the authors' knowledge, an impalement by a flagpole through both lungs and the mediastinum without major lasting damage had not been described before.

What made the careful approach possible was her stability. A patient who is bleeding heavily goes straight to the operating room. Because she stayed stable, the team could take the time for CT, cameras in the airway and gullet, and preparation for a heart-lung machine before anyone touched the pole. The authors' practical lessons are about the pole itself: keep a long impaled object completely still from the scene onward, shorten it only with great care so that it fits in the scanner, and take it out only once the surgeon can see everything it might injure.

Closing the record

What this case teaches

A 61-year-old woman slipped between two boats and fell onto a flagpole that went through both lungs and the middle of her chest, between her windpipe and gullet and just above her aorta. She stayed awake and stable. Firefighters cut the pole at the scene and again in the hospital so she would fit in the CT scanner, while someone held it still for hours. Surgeons opened her chest across both sides, drew the pole out under direct vision and repaired her lungs; she lost about half a cup of blood. A nerve injury left her right hand weak, but nearly three years later she could make a fist again. When something is through the chest, the object is often holding things together, and getting it out safely is about control: keep it still, see the whole path first, and remove it only when every structure it touches is in view.

Was this case worth your time? Buy the next one a coffee ($3), or support MedicaseHub monthly.

Next case · MC-057She arrived with a fence post through her chestAn unbelted driver hit a metal fence and a post went through her lower chest. Rescuers cut it and left it in. Removing it took two operating tables.Read it →

Want the next case like this?

When a new case is written up, it comes to your inbox: the story, the diagram and what it teaches. No schedule and no filler. Unsubscribe in one click.

Free · no spam · your address is never shared · built with Kit

Adapted from Schumacher J, Lang G, Opitz I and Schneiter D, “A Swiss flag through the chest: a case report of a rare transmediastinal impalement,” International Journal of Surgery Case Reports 2026;138(9):3889-3894, from the Department of Thoracic Surgery, University Hospital Zurich, Switzerland. The accident, the findings, the operation, the recovery and the three-year follow-up are as reported there, summarised in the author’s own words; the mortality figures and lessons are those the authors give in their introduction and discussion, and the anatomical explanations are from standard references. The photographs and imaging are reproduced from the paper under its Creative Commons Attribution licence (CC BY 4.0); individual panels were cropped from the published figures and resized. The diagram is original to MedicaseHub, is simplified, and may be reused freely under CC BY 4.0. This article is not medical advice. If something is stuck in someone, do not pull it out: keep it still and call emergency services. Read the full disclaimer.

Related cases

  1. MC-057EmergencyShe arrived with a fence post through her chestAnother pole through the chest, and an operation built around getting it out safely.
  2. MC-062EmergencyHe fell 20 metres, and a piece of wood ended up completely inside his chestAnother object inside the chest that could not simply be pulled out.
  3. MC-043EmergencyIt ran from his pelvis to his neck and missed every major vesselAnother impalement that should have been fatal, and wasn't.

← All cases