She slipped between two boats and fell onto the flagpole
A 61-year-old woman fell onto a boat's flagpole. It went through both of her lungs and the middle of her chest, passing between her windpipe and gullet just above the aorta. She stayed awake and stable the whole time, and it was too long to fit in the scanner.
- Specialty
- Thoracic surgery, trauma
- Patient
- Woman, 61
- Accident
- Slipped stepping from one boat to another and fell onto a flagpole
- Path
- In through the left chest, across the middle of the chest above the aortic arch, into the right lung
- On arrival
- Fully alert, normal blood pressure and pulse, 2 hours after the fall
- Operation
- Chest opened across both sides (clamshell); pole drawn out; 130 mL blood lost
- Day 18
- To rehabilitation; right hand weak from nerve injury
- ~3 years
- Can make a fist; some hand muscles still paralysed
- the fallbetween boats
- 2 hourstoo long to scan
- theatreclamshell
- 3 yearsthe hand
One wrong step
The woman was 61. She slipped while moving from one boat to another and fell onto the boat's flagpole, which went into her chest.
The local fire brigade cut through the pole with a cold saw, a metal-cutting saw that produces little heat or sparks, so she could be freed and moved with the rest of the pole still in her. She was given tranexamic acid, a drug that slows the breakdown of blood clots, and oxygen, and was flown about 43 miles to the major trauma centre at University Hospital Zurich in Switzerland. She arrived in the trauma room two hours after the accident.
Awake, stable, and impaled
She arrived fully alert, with a normal blood pressure and heart rate. She needed some extra oxygen through a face mask but had no other injuries. The doctors heard a wheeze over the top of her left lung; her heart sounds were normal.
PhotographThe cut end of the flagpole in her left side on arrival, with the flag still attached. Graphic. Tap to show.

A chest X-ray showed a metal object about 30 centimetres long crossing her chest from the left side towards the right. It had gone in very far back on the left and was angled upwards, towards the neck, which meant it had almost certainly passed through the middle of the chest, the mediastinum, where the heart, the great blood vessels, the windpipe and the gullet all sit close together.
Because she was stable, the team wanted a CT scan with contrast to map exactly what the pole had hit. The pole was too long to go through the scanner, so the fire brigade came into the hospital and cut it shorter again with the cold saw. Throughout, from the scene to the operating table, someone held the pole still so it could not move inside her. The authors write that one person was given that single job for several hours.
The CT showed the path. The pole had entered the left side of the chest between the third and fourth ribs, gone through the upper lobe of the left lung, crossed the mediastinum close to the left subclavian artery, the artery to the left arm, narrowly missing the arch of the aorta, and passed between the windpipe and the gullet before ending in the tip of the right lung. There was a small collapse of both lungs from air leaking into the chest.


The CT could not completely rule out a tear in the windpipe or the gullet, so before surgery the team looked inside both with cameras: a bronchoscopy for the airway and an oesophagoscopy for the gullet. The pole was pressing on the front wall of the gullet and pushing the windpipe slightly aside, but neither was torn.
Opening the chest from side to side
The team prepared for the worst. Catheters were placed in the artery and vein in her groin so that she could be put on a heart-lung machine quickly if a major vessel started to bleed, and a breathing tube with two channels was used so that either lung could be ventilated on its own.
Two senior thoracic surgeons operated. They used a clamshell incision: a cut across the front of the chest along the fourth rib space on both sides, through the breastbone, so that the whole front of the chest opens upwards like a lid. It gives access to both lungs and to everything in the middle of the chest at once, which is what a pole crossing from one side to the other required, and it is the incision the hospital routinely uses for lung transplants.
Inside, the pole had gone through the upper lobes of both lungs and across the mediastinum just above the aortic arch. It was drawn out slowly under direct vision. The aorta had only a minor injury to its outer layer, which was not bleeding and was left alone. The tears in both lungs were stitched, and a small artery in the left upper lobe was tied off. The windpipe was not injured. Four chest drains were placed. The operation took two and a half hours, and she lost 130 millilitres of blood, about half a cup.
PhotographsViews inside the open chest during the operation. Graphic. Tap to show.


The one lasting injury
Her breathing tube came out seven hours after surgery, and she spent three days in intensive care. Camera checks of the gullet and airway on the first and second days confirmed they were intact. The last chest drain came out on day 8, after an air leak from the injured lungs had settled.
After the operation she had tingling, nerve pain and weakness in her right hand, especially in bending the wrist and moving the fingers. An MRI showed swelling and bruising around part of the brachial plexus, the bundle of nerves from the neck to the arm, on the right, with no nerve cut through. The authors think the pole, which ended near the top of the right side of the chest, irritated those nerves. They note two other possible contributors: she had had an operation on a nerve root in her neck on the same side three years earlier, which no one knew about when she arrived, and arm positioning during chest surgery can stretch these nerves.
She left hospital on day 18 for a neurological rehabilitation centre. At three months she could lift her right arm and turn her hand, with largely normal feeling. Nearly three years after the accident, nerve tests showed the muscles supplied by two of the hand's three main nerves recovering steadily, while those supplied by the third, the ulnar nerve, were still paralysed. She could make a fist again, her nerve pain was controlled with medication, and physiotherapy and occupational therapy were continuing.
Why the middle of the chest is so dangerous
Injuries that cross the mediastinum are among the most lethal in trauma. The authors cite death rates of up to 60%, and in gunshot wounds through the mediastinum about half of patients have an injured major vessel. The heart, the aorta and its branches, the windpipe and the gullet are packed so tightly that anything crossing the space rarely misses all of them. To the authors' knowledge, an impalement by a flagpole through both lungs and the mediastinum without major lasting damage had not been described before.
What made the careful approach possible was her stability. A patient who is bleeding heavily goes straight to the operating room. Because she stayed stable, the team could take the time for CT, cameras in the airway and gullet, and preparation for a heart-lung machine before anyone touched the pole. The authors' practical lessons are about the pole itself: keep a long impaled object completely still from the scene onward, shorten it only with great care so that it fits in the scanner, and take it out only once the surgeon can see everything it might injure.
What this case teaches
A 61-year-old woman slipped between two boats and fell onto a flagpole that went through both lungs and the middle of her chest, between her windpipe and gullet and just above her aorta. She stayed awake and stable. Firefighters cut the pole at the scene and again in the hospital so she would fit in the CT scanner, while someone held it still for hours. Surgeons opened her chest across both sides, drew the pole out under direct vision and repaired her lungs; she lost about half a cup of blood. A nerve injury left her right hand weak, but nearly three years later she could make a fist again. When something is through the chest, the object is often holding things together, and getting it out safely is about control: keep it still, see the whole path first, and remove it only when every structure it touches is in view.
Was this case worth your time? Buy the next one a coffee ($3), or support MedicaseHub monthly.
Next case · MC-057Want the next case like this?
When a new case is written up, it comes to your inbox: the story, the diagram and what it teaches. No schedule and no filler. Unsubscribe in one click.
Free · no spam · your address is never shared · built with KitRead the original paper: doi.org/10.1097/RC9.0000000000000873
Adapted from Schumacher J, Lang G, Opitz I and Schneiter D, “A Swiss flag through the chest: a case report of a rare transmediastinal impalement,” International Journal of Surgery Case Reports 2026;138(9):3889-3894, from the Department of Thoracic Surgery, University Hospital Zurich, Switzerland. The accident, the findings, the operation, the recovery and the three-year follow-up are as reported there, summarised in the author’s own words; the mortality figures and lessons are those the authors give in their introduction and discussion, and the anatomical explanations are from standard references. The photographs and imaging are reproduced from the paper under its Creative Commons Attribution licence (CC BY 4.0); individual panels were cropped from the published figures and resized. The diagram is original to MedicaseHub, is simplified, and may be reused freely under CC BY 4.0. This article is not medical advice. If something is stuck in someone, do not pull it out: keep it still and call emergency services. Read the full disclaimer.
Related cases
- She arrived with a fence post through her chestAnother pole through the chest, and an operation built around getting it out safely.
- He fell 20 metres, and a piece of wood ended up completely inside his chestAnother object inside the chest that could not simply be pulled out.
- It ran from his pelvis to his neck and missed every major vesselAnother impalement that should have been fatal, and wasn't.